screwfix electric hob. I would like to have them replaced by by both electric hob and electric oven. screwfix electric hob

 
 I would like to have them replaced by by both electric hob and electric ovenscrewfix electric hob  The Scolmore one in your first link has two cable outlets

I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. 98 Inc Vat. 2 x Ceramic Plates. Order Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm at Screwfix. Peter160482 New Member. CDA 30cm 2 Zone Domino Ceramic Hob. I've added a couple of wiring options. A user asks how easy it is to change an electric hob for another one at home. Buy Light Bulbs at Screwfix. Easy power isolation. #2. Either switch it off and use matches until it dries out or if you know which knob got wet you could just blow-dry that one until it stops clicking. wrighty wrongy Member. Control Type: Touch. Delivery. As you probably know, induction hobs work by turning electricity into magnetic currents that in turn agitate the food molecules in the pan, not by actually heating the pan. It doesn't trip every time I switch it on. I edited my reply and agree. 2 x Plate Sizes. replaced hob and still doing it. 4 Kw total load induction. now there is a electric hob and electric oven. Twin Grill. A really interesting question and you are correct there is no minimum distance specified in any regulations, regarding electric hobs. 68 per month*. Can I run the oven off the same supply if I tee into. If you were to measure from the wall to the edge of the heat source, that would be more than 50mm. Over 40,000 products. PayPal accepted online. Page 2 of 2 < Prev 1 2. The distance between the top of the hob and the top of the. The pan base heats up. HOTDOG ø, May 26, 2008. The other question i have concerns the hob. (70) From £90. We have 6mm T&E from the CU to a hob isolator switch on the kitchen wall. 5kw for the hob, a total of 10kW. FREE next day delivery available, free collection in 1 minute. View all: No Nonsense Spray Paints. Samsung NZ84F7NC6AB_BK 80cm Electric Hob - Black (2) £ 818. "drop test " on the meter to make sure that the. 6 A) - so a worst-case total of 10. Ah ok so it's the same wiring as an electric hob, but slightly more complex is that right? HannahBanana, Sep 13, 2017. If you come up with a figure of much more than 32 amps don't panic, it could still be ok if diversity is taken into account. Ceramic is the most common electric hob, and we’ve put together our picks of the best. Discount applied in basket. Having a switch on the wall doesn’t mean you can install an electric hob and oven, it might only be rated for supplying the clock and ignition on the gas cooker. under corgi rules whether you are competant or not . Suitable for Indoor use. I've checked the voltage being fed to the hob outlet and its 240v on the live and 0 on the neutral. Cooke & Lewis CSB60A Built- In Single Electric Oven Stainless Steel 595mm x 595mm. #7. The MCB is rated at 40a on the consumer unit and has a 6mm twin and earth clipped to the basement rafters to the hob on the island in the kitchen. The most practical way IMHO is to install a single socket in an adjacent base unit so you can plug in the hob ignition. 2) 220-240V 2 ~ H05V2V2-F 3G 2. 49 Inc Vat. 1/5. 8 & 6. £ 5. Several light coats will give a better finish than a single heavy coat. Coloumb Screwfix Select. Automatic switch-off timer and up to 9 adjustable power levels per zone. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of stores Hi mate thanks for reply im trying to avoid anymore cost if i dont have to, this house has already cost me enough lol, im guessing the pipe is ok but if your saying it 100% needs a gas safe engineer to cap it then i will get it done, but if your not sure then im trying to get a gas safe engineer to tell me if it needs it or not before i fit the electric hob, hope that makes sense Crabtree Capital 20A 1-Gang DP Hob Switch White with Neon (9718J) compare. The current setup is as follows: CCU>1xB32 MCB>connected to 2x red cooker switches: - Switch 1: connected to hob above. Delivery Next day available. 5mm H05 flex for oven to outlet plate as specified in manufacture manual says the max wattage for this size cable is 3860w. I want to get a new hob. 5Kw (14. The built-in Neff B57CR22N0B Slide & Hide Electric Oven is spacious and packed with plenty of different functions that allow you to cook the way you want. Question is cable supplied with hob is 1. I have an existing single one electric oven & standard electric hob, both hardwired into a flush dual outlet plate (one gang). 3 KW (max. most hobs need minimum of 4mm cable and a 32 amp fuse at the consumer unit supplying only the hob. Will have a single electric oven and a gas hob. FREE next day delivery available, free collection in 1 minute. HannahBanana New Member. com. stateit Screwfix Select. Order online at Screwfix. 97 Refurbished options available from £159. Thread by: Aimee88 , Feb 4, 2022 , 6 replies, in forum: Electricians' Talk Showing results 1 to 1 of 1Hendo New Member. Pay your way. It has starting getting small cracks in the worktop around the edge of the hob next to the ring I use the most. New ceramic electric hob to replace existing gas. 590 mm. 7 Strands Per Core. Unfortunately there are no regs for electric hobs of any type. 5mm2 ring which is protected by a 32A MCB. 60 days free credit available. So I am wondering does diversity apply to the combined total wattage of both the appliances or just the oven. 5KW and I have put it on a 32A breaker, with 6mm cable. The process you describe above is more like how a microwave oven works. The switch will act as an isolation switch for both. 7Kw so by my calculation that means the maximum current in the circuit = 10700/230 = 46. Raised Square Profile. £289. So we divide the 10kw, by 230 volts =43. £7. There are many different ways, 3 circuits has its benefits if you have room in cu. Bob C New Member. com. Hi Both front and back left hand side of hob wont work, both rings on right hand side is fine. I'm just trying to confirm as to whether I can wire a second appliance - the new electric hob - into the same 32A fused 'socket' as the cooker, I don't need to take. Check the kW rating of the hob, in most cases a 6. However, the oven will still not fit because of a pipe coming down from the hob itself. One other thing is that the hob as well as other appliances connect to a 80amp mcb as we had the kitchen redone a few years ago. 2 x Ceramic Plates. Perhaps I should persuade the my mother-in-law to get a decent electric hob ! Sam, Jun 16, 2006 #5. Oven is only rated at 2. You simply want to find out which fuse is on the Oven circuit and what its rating is (guessing 32A). 4 x Burners. Now obviously this is not good and ive recommended a different layout of the kitchen and to try get the hob above some cupboards where theres. P=Power, V=Volts, and I = amps P = V x I P/V = I 8800/240 = 36. View product Smeg SI4642D_BK 60cm Electric Hob - Black £. lee49 New Member. But if i turn the isolator switch on with the hob disconnected its fine. Its a good bet that the socket will fail after some use. Having ploughed through loads of specification on AO. 5cm. If it works with L1 and L2 together, with the marking of “25A” usually meaning per phase, it is going to give 50A on the neutral at full load. 04 amps. Best electric hob: At a glance. Bob C New Member. Apple Pay accepted in store. Permanent Adhesive. Mike83 Screwfix Select. Having an existing gas hob and electric oven (under counter) replaced. I have B32 and want a single oven and induction hob. You need to read it properly: The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 55cm from electric cookers and 70cm from gas or mixed cookers. alex250 New Member. Buy any 10+ Save 10% - View Offer. and you may find your hob requires even moreFront-mounted touch controls. When the electricity network goes down, gas cooking still works, except the electric igniter, so you need a a lighter/matches. Each of the ovens is 5. com. com. Screwfix Community Forum. You don’t actually need a wide bead to seal, although you can, just a tiny bit of sili in the mm or so gap. (62) From £349. That means the top of the pan supports not the worktop. The work top is 600mm. I originally thought this meant to use either 5 or 3 cables. Repair Service Action. Dr Bodgit Super Member. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. Requires 25mm Back Box. We’re replacing our gas oven with an electric oven but keeping the gas hob. metrokitchens Screwfix Select. Add to wishlist. Paint over rust on cooker hob. Sign in / Register. It comes up with half a dozen to choose from. The hob will need to sit into some form of worktop. There is a switch on wall by oven. Boost function. Need Help. The sensor touch panel with an LED screen is easy to. 5 mm cables or 3x2. Brown, Black, Blue, Grey & Green/Yellow Cores. Also the RCD will save you if the hob has a serious electrical fault. Solvent-Free. A 3kW kettle is only on for say 2 or 3 minutes at a time, whereas, a hob could be on for an hour or more at a time. 79Inc Vat. Check out our latest offers on home appliances. Upgrade your kitchen with a hob from premium brands like AEG, Siemens and Bosch. Child Safety Lock Mechanism. Extract and recirculate kitchen steam and fumes. Click & Collect. 9% APR representative (variable)* +1 more offers. stateit, Jan 11, 2014. Page 2 of 2 < Prev 1 2. Buy Cooker Hoods at Screwfix. 5kW blasting away in all. 8kw. I was going to fit a dual appliance outlet, and a 13amp switch, and wanted to confirm if the 45a switch should go before or after the dual appliance outlet (see diagram). 375. I have a new electric hob , the earth terminal is marked but the other 2 are not so does it matter which goes to the live and. Improve Kitchen efficiency and hygiene. 5mm2 T&E from spur to 30A jb, flex from jb to hob, 2. No Timer Function. Please do not return to store. Repair Service Contact. No, it's not the same. Wiring a 7. 3. I purchased an electric built under double oven, the first couple wouldn't fit but now I have one with a slant at the back to allow for the gas pipe on the back of wall. The regs allow a separate oven and hob to share the same supply and control unit provided that they are not more than 2 metres apart or from the control, that you apply diversity, that is you add the hob and oven current together, take the f1rst 10A of that total and add 30% of the remainder (add 5A if a socket is fitted to the cooker control, don't do. 6mm would be ok on a short run, and if not subjected to thermal insulation in walls or ceilings, or high ambient temperatures. Buy any 10+ Save 10% - View Offer. Don't be tempted to use masses a small bead. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. com. 25. More precise cooking. 3 phase supplyHi need bit of advice hope you guys can help recently bought a new Neff double oven,electric hob and microwave,all 16amp rating 240 volt. My question is the installation guide states is should be "connected using 3 x 6mm / 3 x 2. Hi, I would like to replace an existing electric oven & gas hob with a new electric oven & electric hob. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. Discount applied in basket. I think I might be able to explain why the hob has two cables. £164. FREE next day delivery available, free collection in 1 minute. Dimensions: (H)6cm x (W)60cm x (D)53cm. Dr Bodgit, Oct 24, 2017. com it seems the vast majority of the cheaper single ovens only take 13amps, some even come with a 13 amp socket. 2. Most do come with flex attatched normaly about 2 meters long. kitchen appliances. Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. Home Forums > Screwfix Community Forum > Plumbers' Talk > Propane Gas Hob. He has backed ou and need to revert to NAPIT for advice. Black PVC Sheathed Cable. I'm simply confused by the wiring diagram for the hob. An induction hob is an electric hob, just has an increased power rating (normally) Dr Bodgit, Sep 13, 2017. This is a metal box that has an oven, sometimes a separate grill and 4 heating rings. 7 kW into a single ring, where the 13A socket can only. 6 x 49. 5MM2. It's explained in the hob manual. 5mm" and that "for this connection a power lead of wire type H05VV-F should be used". 0800 324 7818. same thing but the oven and the hob are in separate boxes! So, hob is 7. In the main an electric hob needs letting into the work top, where a gas one has a recess in the design to catch spills, what you don't want is for the spill to run off the hob onto the work top making any items on the work top wet, my induction hob is around a 1/16 of an inch lower than work top. 2 x Plate Sizes. Repair Service Contact. 5kW for the oven and say 6. 99% of hobs the cutout is 10mm smaller than the overall size of the hob so a hob with a cut out of 492 (490+2) will actually be at least 510mm deep overall so will cover the existing cutout by 6mm either side. Sparkielev said: ↑. Deals and Offers. 00 Save £10. Hi there. My question is the. Buy Electric Hobs at Screwfix. Make sure that the socket you test it on is RCD protected. Click & Collect. 21. 5R electric oven under the gas hob. The Sigma3 countertop depth is the standard 600 mm but the splashback thickness (approx 15 mm) clearly reduces the useable depth to less than the minimum 600 mm required by Neff. 5 mm flex. Several options available. Instant heat and easy to manipulate to the required temperature. Steve. Having googled the wire type its some sort of flex cable. Bought the cheapest 4 zone non branded on Appliances Direct and it's been fine now for 5 years or so, we paid about £150 for it then. The combined load of these appliances is not going to be greater than that of the existing free-standing cooker. All on a 40amp breaker or would it be best to de-rate down to. To neatly finish off the paint job I am looking for a heat safe sealer to seal around the end of the hob / slightly underneath it where I can’t quite get the paint. Screwfix Community Forum. Filters. Also the supplied cable for the oven seems a bit lightweight to put into a connection plate. The problem is that our current integrated oven and built in hob are situated under a window, and a kitchen designer has told us we cannot have a new gas hob in the same place. (a common problem on older oven and hob elements). As others have said, look for the rating label on the hob, to use a 13A plug successfully it should not exceed 3. But the hob draws 7. Screwed Faceplate. 2 x Ceramic Plates. Dan Parkinson, Jul 27, 2020. 2A (=10. Single oven, electric hob and cooker hood all fed off one 13A switched spur. Page 1 of 1. Child Safety Lock Mechanism. 30 day money back guarantee. Just put them both underneath the Hob and stop worrying. It will need a 13A fuse, which will come with it. You do not need to change the MCB. Raised Square Profile. £11. Hobs however, usualy require a dedicated 4/6mm 32A+ supply. Is is normal practise to wire both appliances into the outlet that is supplied by the 45A DP cooker switch on the wall? I appreciate your time if you can. . 2 If that is the only gas inlet you could consider running the. Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. 5cm. Available in styles & finishes to suit your kitchen. W x H x D: 260 x 90 x 7mm. Delivery. Cooke & Lewis CGSBCER60 560mm Ceramic Hob, Hood & Splashback Black (145KH) compare. Yes, as pointed out above. Screwed Faceplate. Unlike gas hobs, there are several types of electric hob, and choosing the right one for you can be confusing. Basket. 99 Inc Vat. Inline Relays. The Happy Builder Screwfix Select. furious_customer, Oct 2. Buy any 10+ Save 10% - View Offer. Below is the specifications for my old hob (which is now out of stock), underneath is a link to a new one i think will be a like for like swap, it is the same size and same amp, is there anything else i have overlooked? Model name/number CLIND1BK-C Colour Black Material Ceramic Fuel Electric Hob type Induction Number of burners 4. £8. Free next day delivery available. Should the product require repair please contact our repair service to arrange collection and repair. 3kw induction hob on its own radial circuit protected by a 32amp MCB. hob spec: -PVC insulated connection cables type ho5 vv-f or ho5v2v2-f with yellow-and-green protective conductor, or other equivalent superior cables. I lifted the old hob to see where the wire goes. My wife would like to replace the range cooker with one that has an electric oven and an induction hob. White PVC Sheathed Cable. FREE next day delivery available, free collection in 1 minute. The pan base heats up. Allow to dry between coats. Can I supply both hob and cooker with this supply or do I need to run a seperate supply from consumer unit for each appliance, cooker is 4kw and hob 7. I need to replace a gas hob with an electric hob and there is already an electric oven there. The induction hob will require max of 6kw/240v = 24 amp. Delivery 7 days a week Pay your way. Screwfix Community Forum. HC9621FR Five zone ceramic hob. Repair Service Action. I'm about to replace a few kitchen units and want to replace the electric hob and oven with ones that are rated a little higher. UK call centre ready for your call 24/7. unphased Screwfix Select. mb New Member. 85 kg. stateit Screwfix Select. Hi, I have some rust on the trim around my electric cooker top and I would like to try and repair it. Our Lowest Price Ever. Buy any 10+ Save 10% - View Offer. Worktop 20mm. Ideally you need an electrician who is capable of undertaking kitchen fitting and knows a gas fitter. Ah no. I usually paint the exposed chipboard edge with waterproof PVA (several coats), but you could use yacht varnish. 2A) Applying diversity gives 100% of the first 10A plus 30% of the remaining 35. Huge range of cap fittings, shapes, wattages and technologies. 49 Inc Vat. Presently, the oven is fed by the CU through a 32A MCB via a 45A counter-top cooker switch, using 6mm T&E. If the whole area is grimy, then use a toothbrush with the WD40 to clean thoroughly around the button shaft and wipe it clean. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. 0mm H05 flex for hob to outlet plate as it’s current demand is 30. Can anyone recommend a paint I can use? or would you not recommend trying to do this?. The existing socket is most likely on 2. Read on to see which ones made the cut. 3) 220-240V 3 ~ H05V2V2-F 4G 2. £5. Frustrated female New Member. The problem is the customer. 2 x Plate Sizes. The new electric hob manual states; 220-240v total consumption: 6700w fuse 25a / 16a x 2 cable type: HO5v2v2 - f 3x 2. Have a good ‘un Bazza, Oct 2, 2018 #22. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. kitchen appliances. 1A, min fuse protection rating 30A. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric hob. Raised Square Profile. Ask a question. Electrolux KGS7536X 5 Burner Stainless. Hi all, Currently in the process of modernising our extremely old kitchen. What there is though is manufacturers fitting instructions, which should include the minimum distance from combustible material. 56 Amps total, with diversity. There is nothing wrong with this and it's within the Regs and done all the time. Divide the rating in watts by 230 (volts) to get the current draw figure. Most are under 3 kW (approx rating for a 13A plug) 4 ring hob, probably not; unless it's a 2 ring 'domino hob' pulling less than 3 kW. Old hob specs from data sheet below. 1 2. On the new Beko hob it simply states use 5x1. I want to replace this solid plate hob with a ceramic one. 5mm 3 core flex. British General 900 Series 45A 1-Gang DP Cooker Switch White with Neon (67918) (26) £7. sinewave, Mar 24, 2007. So I think I can just plug the oven into the ring main and use the 32amp feed for the hob. Product code: 401376. 3/5. HiNeff N50 T26BB59N0 Cast Iron Gas Hob - Stainless Steel. 2 x Plate Sizes. You need to have a look at every joint in the cable run. The circuit supplying your existing oven will most likely be a standard 32A cooker circuit wired in 6mm2 T&E. 4. I went round the house turning everything off and finally identified the culprit - my gas hob! I turned it off at the isolator switch above the worktop and then I. Buy any 10+ Save 10% - View Offer. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesHi mate thanks for reply im trying to avoid anymore cost if i dont have to, this house has already cost me enough lol, im guessing the pipe is ok but if your saying it 100% needs a gas safe engineer to cap it then i will get it done, but if your not sure then im trying to get a gas safe engineer to tell me if it needs it or not before i fit the electric hob, hope.